SOFRASER_logoLogo_sofraser Process ViscometerViscometer application
Portable_viscometer

THERMOSET MIVI 8003 : Viscosity measurement of any fluid at a required constant temperature*

Technical Characteristics
 

1) Exproof classification for the cell parts

2) Viscosity range (at reference temperature) :1-100 mPa.s ; 10 - 1000 mPa.s : 100 - 10 000 mPa.s

Accuracy : + 1% full range.

Repeatibility : + 0,5 full range

3) Real response time : 2 to 5 min

4) Delivered information :

  • Digital display for viscosity and temperature.
  • Viscosity and tempearture outputs : 0/ 4-20 mA DC 500 ohms galvanically isolated.
  • RS 232C link.
 
  • Viscosity and temperature alarms
  • Others possibilities on request. (Consult us)
5) Required power : 230 Vac, single phase, 50-60 Hz, 1kVa + pressured air, 7 bar, 0,5 m3/h

6) Operating conditions :

  • Maximal temperature at the cell : 200°C
  • Reference temperature according to the requirement.
  • Maximum working pressure : 25 bar (other on request)
Agreements

download

Download technical presentation

*Whatever was its original one, with short time response : 2 to 5 minutes